Micro water quality monitor

Micro water quality monitor

Model:FT-WMSM

Brand:tianqiong

Micro water quality monitor is used to monitor data such as total phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, and permanganate index parameters.
  • Product details
  • Related products
  • Related articles

1.Micro water quality monitor product introduction:

Micro water quality monitor is used to monitor data such as total phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, and permanganate index parameters.In response to the national policy on strengthening environmental protection, maintaining natural ecological balance, and promoting the sustainable development of the national economy, our company has independently developed and produced small outdoor water quality automatic monitoring station FT-WMSM, which is independently developed and produced according to market needs, combines the methods specified in the national standard with advanced computer technology to realize full automation of the measurement process and can be widely used in surface water quality monitoring of rivers, lakes and other surface water.

The factors that cause surface water eutrophication are mainly chemical factors such as N, P, organic matter, HN4- in water bodies.Therefore, monitoring chemical indicators such as total phosphorus, total nitrogen, ammonia nitrogen, chemical oxygen demand, and permanganate index in surface water has become a necessary task.In conjunction with the conventional five parameters (dissolved oxygen, turbidity, conductivity, temperature, and pH) to monitor the reaction water environment indicators simultaneously.

2.Micro water quality monitor monitoring principle:

This outdoor water station adopts the integrated design principle, including water production and distribution system, detection unit (total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and five measurement modules for conventional five parameters), quality control unit, and auxiliary unit (waste liquid collection, lightning protection, air conditioning, etc.).The core unit is the detection unit, total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and chemical analysis methods strictly follow the national standards.The conventional five-parameter indicators (dissolved oxygen, conductivity, turbidity, temperature, pH) are measured using multi-electrode integration.

3.The main specifications and standards of Micro water quality monitor:

According to design documents, equipment, materials, and construction, it must meet the current requirements of the engineering construction standards and specifications of the People's Republic of China, provinces, autonomous regions, municipalities or industries.The technical standards and specifications followed by this project are as follows:

(1) "Technical Specifications for Monitoring Total Water Pollutant Emissions"

(2) "Methods for Monitoring and Analysis of Water and Wastewater" (Fourth Edition)

(3) "Environmental Water Quality Monitoring Quality Assurance Manual"

(4) "Technical Specifications for Surface Water and Sewage Monitoring" (HJ/T91-2002)

(5) "Technical Guidance on Water Quality River Sampling" (HJ/T52-1999)

(6) "Technical Requirements for Automatic Chemical Oxygen Demand Water Quality Analyzer" (HJ/T377-2007)

(7) "Technical Requirements for Automatic Water Quality Analyzer of Permanganate Index" (HJ/T100-2003)

(8) "Technical Requirements for Automatic Ammonia Nitrogen Water Quality Analyzer" (HJ/T101-2003)

(9) "Technical Requirements for Automatic Analyzer of Total Nitrogen Water Quality" (HJ/T 102-2003)

(10) "Technical Requirements for Automatic Analyzer of Total Phosphorus Water Quality" (HJ/T 103-2003)

(11) "Technical Requirements for Automatic pH Water Quality Analyzer" (HJ/T96-2003)

(12) "Technical Requirements for Automatic Conductivity Water Quality Analyzer" (HJ/T97-2003)

(13) "Technical Requirements for Automatic Turbidity Water Quality Analyzer" (HJ/T98-2003)

(14) "Technical Requirements for Automatic Water Quality Analyzer for Dissolved Oxygen (DO)" (HJ/T99-2003)

(15) Relevant standards and specifications of the country and industry

(16) "Environmental Protection Industry Standards of the People's Republic of China" (HJ/T98-2003)

(17) "Building Lightning Protection Design Code"

(18) "Power Supply and Distribution System Design Specifications"

4.Micro water quality monitor product features:

1.Adopt integrated automatic water quality monitoring station, which can measure multiple elements at the same time;

2.Various analytical and detection units, with low detection limits and meet the requirements of online surface water monitoring;

3.The water collection and distribution unit has water sample pretreatment and backflushing functions, with low failure rate and easy maintenance;

4.The UPS uninterruptible power supply can be optionally equipped to ensure that the water station completes the cleaning process when the power is out;

5.It can be equipped with video surveillance equipment, with real-time remote monitoring function, and realizes all-round monitoring;

6.The area of the whole machine covers a small area of ≤2m2;

7.Equipped with waste liquid separation and waste liquid collection unit,

8.Meet the collection of waste liquid for more than two weeks; be equipped with lightning protection units to ensure stable and reliable operation of the system;

9.Intelligent constant temperature system, equipped with cabinet-type heating and cooling air conditioning, to ensure that the water station operates at the specified working temperature.

5.Micro water quality monitor technical parameters:

projectPerformance indicators of total phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, permanganate index parameters
Total phosphorusAmmonia nitrogenTotal nitrogenChemical oxygen demandPermanganate index
Reference standardsGB11893-89HJ/536-2009HJ 636-2012HJ828-2017GB11892-89
Measurement range0.02~2mg/L (scalable)0.1~5mg/L (scalable)0.1~10mg/L (scalable)15~2000mg/L (scalable)0.5~20mg/L (scalable)
Detection limit≦0.01mg/L≦0.10mg/L≦0.1mg/L≦15mg/L≦0.1mg/L
drift±5%±5%±5%±5%≦0.5mg/L
Precision≤5%≤5%≤5%≤5%±5%
Display error±5%±5%±5%±5%≤5%
Voltage impact±10%±5%±10%±5%±5%
Temperature influence±5%±5%±5%±5%±5%
consistency≥90%≥90%≥90%≥90%±5%
Sampling cycleTime interval (any adjustable 20~9999min) and hourly measurement mode
Calibration cycle1~99 days can be adjusted at any time
Maintenance cycleUsually once a month, each time for about 60 min

Micro water quality monitor regular five-parameter technical indicators:

Five-parameter performance indicators
Measurement methodpHDissolved oxygenConductivityTurbiditytemperature
Glass electrode methodFluorescence quenching methodFour-wire electrode method90 degree scattering light methodThermal resistance electrode method
Reference standardsGB/T6920-86GB/T11913-89GB/T6908-201GB/T13200-91GB/T13195-91
Measurement range0~140mg/L ~ 20mg/L0ms/m~500ms/m0NTU~1000NTU0~50℃
drift±0.1pH±0.3mg/L±1%±5%——
Precision≤0.1pH≤5%≤1%≤5%——
Display error±0.1pH≤5%±1%±5%——
Voltage impact±0.1pH≤0.3mg/L±1%±5%——
Temperature compensation accuracy±0.1pH±0.3mg/L±1%————
Water temperature error————————±0.2℃
Calibration cycleUsually twice a month
Maintenance cycleUsually once a month, about 30 minutes each time

Micro water quality monitor whole machine parameters:

The whole machine parameters
Control unitARM9 embedded industrial control system
Display unit15-inch color touch screen control
Temperature control systemEquipped with dual-purpose air conditioning
UPS voltage-regulated power supply (optional)The UPS uninterruptible power supply can be optionally installed.In the event of sudden power outage, the measurement and cleaning process can be completed.
Lightning protection unitHave lightning protection capabilities
Power requirementsAC 220 V±22 V, 50 Hz±0.5 Hz
Communication interface2-channel RS485, supports 4G wireless transmission
The power of the whole machine≦2500W (including external pump, air conditioner power\maximum power during operation)
Ambient temperature(5~40)℃
External dimensionsHeight 1900mm×width 1480mm×deep 960mm
Water station weight300kg

6.Micro water quality monitor configuration list

Serial numberProduct Namequantity
1Stainless steel outdoor cabinet (including air conditioning)1 set
2Electrical units (PLC, relay, empty switch, switching power supply, lightning protection)1 unit
3Display unit (including 15-inch large screen, microcomputer control program)1 set
4Water collection unit (pipe, sampling pump, float)1 set
5Water distribution unit (electric ball valve, pipe)1 set
6Pretreatment unit (flow cell, liquid level sensor, pressure sensor)1 set
7Permanganate index1 unit
8COD online monitor (optional)1 unit
9NH3N online monitor1 unit
10TP online monitor1 unit
11TN Online Monitor1 unit
12Five parameters (oxygen deoxygen, conductivity, turbidity, temperature, pH)1 unit
13Digital meter1 unit
14Chemical reagents (240 times/month) free1 set

Address:https://tianqiongsensor.com/Micro-water-quality-station/Micro-water-quality-monitor.html