1.VOC detector product overview
VOC detectors are used to assess air quality in homes, industrial facilities, and factories and can detect a wide range of different VOCs and gases.
1.VOC detector generation background and application fields
Volatile organic matter (VOCs) are important precursors for the formation of secondary pollutants such as fine particulate matter (PM2.5) and ozone (O₃), which in turn causes atmospheric environmental problems such as haze and photochemical smoke.With the rapid development of industrialization and urbanization in my country and the continuous growth of energy consumption, the frequency of heavy air pollution in the region is increasing, which seriously restricts the sustainable development of the social economy and threatens the health of the people.Therefore, in order to fundamentally solve the pollution problems such as PM2.5 and O₃ and effectively improve the quality of the atmospheric environment, the country actively promotes the pollution prevention and control of its key precursor VOCs.In recent years, Beijing-Tianjin-Hebei and surrounding provinces and cities have put forward clear construction requirements for the installation and networking of volatile organic compounds (VOCs) fixed pollution sources, unorganized emission monitoring facilities and alarm sensing devices exceeding the standard.
VOCs emission monitoring mainly involves the industries of petrochemical, organic chemical, pharmaceutical manufacturing, industrial coating, mechanical manufacturing, packaging and printing, electronic production, synthetic leather, coating and paint, clothing processing, furniture manufacturing, adhesives, shoes, and oil storage and transportation.At the same time, emissions have the characteristics of unorganized dispersion and organized fixed pollution sources, many types of pollutants, large concentration changes, and uncertain emission time.The TVOC automatic monitoring and alarm system can contact and provide data on TVOC total and key monitoring factor in various industries in real time, and connect online with the competent departments of the Environmental Protection Bureau to realize real-time monitoring of TVOC total emission reduction and pollution discharge charges.
2.VOC detector monitoring range
The monitoring factors of this product are benzene, toluene, xylene, styrene, trichloroethylene, trichloromethane, trichloroethane, diisocyanate (TDI), etc.
Products are based on "Technical Requirements and Detection Methods of Continuous Monitoring System for Meteorological Chromatography of Ambient Air Volatile Organics" (HJ 1010-2018)
Notice on Strengthening the Monitoring of Volatile Organic Materials for Fixed Pollutant Sources
"Determination of total hydrocarbons, methane and non-methane hydrocarbons of waste gases from fixed pollution sources"
TVOC organized emissions online monitoring total organic matter analysis, unorganized emissions, and TVOC flue gas exhaust gas online monitoring;
Analysis of total organic matter in online monitoring before and after TVOC recycling and finishing;
Thermal power plant circulating fluidized bed boiler is used for flue gas monitoring in the combustion control room;
Steel mill rolling heating furnace is used to solve the detection of furnace gas atmosphere when reducing the thickness of oxidative burning or decarbonization layer;
Full hydrogen heat treatment furnace is used to detect whether the radiation tube is burned through and leaked; automobile exhaust emission detection;
Monitoring of waste gas for other industrial kilns and waste incinerators.Industrial emissions of organic volatile exhaust gas;
Quantitative and qualitative analysis of total hydrocarbons (THC) and total non-methane hydrocarbons (NMHX), benzene, dimethylformamide, alkanes, alkenes and cyclic aromatic hydrocarbons in the discharge pipeline;
Complex toxic and harmful organic matter in industrial or chemical areas;
Online monitoring of pollution sources VOC;
Online monitoring of malodor organic sulfides;
Multi-point unorganized discharge line monitoring in the factory boundary
3.VOC detector structure composition
4.VOC detector monitoring principle
Electrochemical, organized
2.VOC detector product features
1.High-performance sensor, good anti-interference performance, stable and reliable pre-processing unit, and adopts diaphragm pump technology.
2.The LCD panel display adopts a 7" touch large screen display, with a full Chinese interface, and a human-computer interactive interface is convenient for operation.The working data is intuitively displayed.
3.Wireless 4G network transmits data, stable and reliable transmission, and automatic calibration function for all software.
4.Supports the backblowing function.The inspection site has on-site sound and light alarm function, and the gas concentration exceeds the standard alarm is immediately alarmed, which is a safety guarantee for dangerous on-site operations.
5.Independent air chamber, no on-site calibration is required when replacing sensors, and the key parameters of the sensor are automatically identified.
6.Adopt microprocessor technology, fast response speed, high measurement accuracy, good stability and repeatability
7.The inspection site has on-site sound and light alarm function, and the gas concentration exceeds the standard alarm is immediately alarmed, which is a safety guarantee for dangerous on-site operations.
8.On-site large screen with backlight multi-parameter LCD display, intuitively displaying gas concentration, type, unit, working status, etc.
9.Independent air chamber, no on-site calibration is required for replacement of sensors, and the key sensor parameters are automatically identified.
10.Automatic temperature tracking compensation for the full range of temperature range to ensure measurement accuracy
3.VOC detector product parameters
Display unit | Display parameters | 7” true color LCD screen (800×480) |
Operation method | Touch operation | |
Transmission Standard | Data protocol | Online automatic monitoring (monitoring) system data transmission standard for pollution sources (HJ212-2005) |
Communication interface | Sensor interface | RS485/Modbus |
Switch interface | 2 routes | |
Data communication | 4G wireless transmission, 1min upload interval | |
Working environment | temperature | -25℃~+70℃ |
humidity | 5%RH ~ 95%RH | |
System parameters | power supply | AC220V±10% 50Hz |
Power consumption | ≤15W | |
Electromagnetic compatibility | IEC Level 3 | |
TVOCs probe | Measurement principle | Electrochemistry |
Sampling method | Pump suction type (2L/min) | |
Range | 0~20ppm,100ppm,1000ppm | |
Temperature and humidity | -20~70℃; 0~~100%RH | |
Display error | ≤10%FS | |
Zero point drift | 1H zero point drift ≤5%FS 24H zero point drift ≤20%FS | |
Range drift | 1H range drift ≤5%FS24H range drift ≤20%FS | |
Response time | <120s | |
Repeatability | ≤5% | |
Measurement error | ≤20% |
4.VOC detector cloud platform
1.Perfect connection capability of government supervision platforms
2.Multitasking, high concurrency, low latency
3.Multi-platform synchronous viewing and multi-dimensional retrieval capabilities
4.Data highlighting alarm and SMS push capability
5.Multi-level management and permission allocation capabilities
6.Support large-screen display and customized development of data
With the increasing demand for ecological protection and sustainable development in modern agriculture, the environmental pollution and pest resistance caused by the overuse of traditional chemical pesticides urgently need to be addressed. Physical pest control methods have gradually become an impor...
In the field of wind power generation, wind measurement is of great significance. Traditional wind - measuring methods, such as wind towers or radars, are effective but have limitations. Wind towers can only measure at fixed locations, while radar equipment is expensive and bulky, making it difficul...
Meteorology encompasses a wide range of elements, such as rain, ice, wind, frost, clouds, and temperature, among others. In the power system, "micro-meteorology" is different from what is described in meteorology. Power micro-meteorology refers to the meteorological conditions in a small s...
All - in - One Weather Sensors represent a significant technological update in the field of modern meteorological monitoring. Through a highly integrated design, it combines traditional discrete measurement modules into a single device, enabling the synchronous collection of all - element meteorolog...