Model:FT-EC09A
Brand:tianqiong
1.Functional requirements for Odor Online Monitoring System
Odor Online Monitoring System provides real-time online evaluation and monitoring of odor pollution, and can monitor a variety of odorous gases through a variety of sensors.Intermittent monitoring or environmental odor monitoring is carried out for polluted areas for 24 consecutive hours.Standard monitoring indicators can simultaneously achieve the types of pollutants specified in the GB14554 standard: odor concentration OU value, ammonia, styrene, hydrogen sulfide, VOCS, trimethylamine, methylsulfide, methylmercaptan, dimethyldisulfide, carbon disulfide.
2.Odor Online Monitoring System Detection Part
The monitoring system is composed of a mixed array of sensors, and the sensor types should be metal oxide sensors, PID photoion detectors, electrochemical sensors, and ETO sensors.
Each sensor can be plugged and unplugged separately, and can be individually calibrated and replaced.
The instrument and equipment calibration operation function is available on site, and there is no need to take it back to the laboratory for calibration.
When using multi-sensor array layout, a working analysis curve that conforms to the artificial olfactory method should be established to simulate a human olfactory system.
3.Odor Online Monitoring System Display Control System
The 7-inch true color LCD touch screen can display all real-time monitoring data and display the working status of the system.
This machine can display historical concentration curves, directly displaying data changes and component proportions in the form of a chart, and real-time data analysis is helpful for event judgment.
Built-in parameter settings, with sensor pre-maintenance function, which can promptly remind customers to maintain the sensor.
The data records can reach at least 1,000,000, with built-in database and USB data copying.
The analyzer can easily upgrade firmware and can be upgraded through a USB flash drive.The system can also perform remote one-click upgrades, parameter configuration modifications and other functions.
4.Odor Online Monitoring System Communication System
The Internet of Things access server adopts a professional communication SOC processor, dual-core and four-thread, with a main frequency of up to 880MHz, and is equipped with large-capacity Flash standard.Based on a powerful hardware platform, feature-rich software can be implemented to meet diverse monitoring applications.The deeply customized JYun operating system supports GPRS, RJ45, ZigBee, LoRa, WIFI, NB-IOT and other communication methods.Flexible networking and secure data transmission.The motherboard and components meet industrial standards, support wide voltage inputs of 9~36V, and the ambient temperature range can reach -20~65℃.
Supports Modbus communication protocol, which can set up and communicate with the system.Data can be transmitted through 4G wireless and wired 485, and can be optionally viewed and monitored data in real time through computer web pages or mobile APPs.
Supports cloud data storage.It can also realize the concurrent transmission function of multiple servers, and can support up to 3 platforms for direct upload.The analyzer supports the connection between the HJ212-2017 network protocol and the data management platform.
The system software has functions such as direct data transmission, data storage, statistical analysis, alarm exceeding the standard, and point writing.
5.Odor Online Monitoring System Preprocessing Part
It has insect and large particulate filtration, dust filtration and water vapor filtration, which can effectively filter oil, gas, water vapor, dust, etc.in the sample gas, effectively reduce interference during the monitoring process, and more quickly, efficiently and accurately unique gas circuit design, effectively solve the interference between gas sensors, and ensure that the sensor works in a steady-state environment.
6.Odor Online Monitoring System Chassis Part
Vertical pole manufacturing process: equipped with lightning rods and grounding: lightning rods are arranged on the top of the pole.The combination of segments is convenient for logistics and transportation.
The entire chassis is made of outdoor plastic powder, and is plasticized at 180° high temperature.The coating has excellent appearance quality and the coating has much higher corrosion and wear resistance.The overall appearance is stable, generous and thick, and has a high load-bearing strength, which solves the problem of serious pole shaking in severe weather such as strong winds.Waterproof level IP53 or above, safe use in outdoor environments.
7.Odor Online Monitoring System Sensor Parameters
1.H2S technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10% |
Repeatability | ≤2% |
Response time | ≤50S |
Zero point drift | ≤±2%FS |
Range drift | ≤±3%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
2.NH3 technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-50PPM |
Display error | ≤±10% |
Repeatability | ≤3% |
Response time | ≤120S |
Zero point drift | ≤±2%FS |
Range drift | ≤±3%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
3.CH4S technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤120S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
4.C2H6S technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤80S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
5.C2H6S2 technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤120S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
6.CS2 technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤120S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
7.C8H8 technical parameters
principle | PID (imported sensor) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤20S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
8.C3H9N technical parameters
principle | Electrochemistry (imported sensors) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤120S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
9.OU technical parameters
principle | MOS (imported sensor) |
Range | 0-1000%OU |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤20S |
Zero point drift | ≤±3%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
10.Particle parameters (optional)
principle | Laser scattering/dust meter (with cutter) |
Range | 0-30mg/m³/0-2000mg/m³ |
11.VOC technical parameters (optional)
principle | PID (imported sensor) |
Range | 0-20PPM |
Display error | ≤±10%FS |
Repeatability | ≤3% |
Response time | ≤20S |
Zero point drift | ≤±5%FS |
Range drift | ≤±5%FS |
temperature | -20℃~+55℃ |
power supply | DC 12V±20% |
Power consumption | <1W |
The Ultrasonic Wind Speed Direction Sensor achieves measurement based on the characteristics of ultrasonic waves propagating in the air. It accurately calculates the wind speed and direction by measuring the time difference of ultrasonic waves propagating in different directions. This non-mechanical...
The Ultrasonic weather station integrates various sensors with different functions, such as sensors for measuring wind speed and direction, sensors for detecting temperature and humidity, and sensors for recording rainfall, etc., all in the same device. This design makes the structure of the weather...
The weather stations used in the agricultural field are called Agricultural Weather Stations. In order to better serve agricultural production, in addition to the conventional meteorological elements, Agricultural Weather Stations will also focus on increasing the monitoring of soil-related elements...
In the production and use of photovoltaic modules, grid breakage is a relatively common and thorny problem. Grid breakage refers to the existence of breakpoints in the silver paste printing of the main grid of the solar cell, which causes the fine grid lines on the solar cell to be open-circuited wi...