Model:TDS-100
Brand:tianqiong
1.Introduction to Fixed Ultrasonic Flow meter
Fixed Ultrasonic Flow meter uses sound waves as a reliable, accurate and maintenance-free method to measure the velocity of a fluid.Fixed Ultrasonic Flow meter combines our company's more than ten years of technical and experience in the production of ultrasonic flowmeters.It uses TI's MFP430FG4618 low-power microcontroller.It is a new ultrasonic flowmeter product with high performance, low price, good reliability and powerful functions.
The product has greatly improved compared with the original ultrasonic flowmeter in terms of measurement accuracy, measurement stability, communication protocol, and convenience of use.At the same time, the component parameters are not adjusted during the production process, the production process is simpler and more applicable, and the product consistency is better, so as to ensure that every factory product achieves the best performance.
2.How Fixed Ultrasonic Flow meter works
When an ultrasonic beam propagates in the liquid, the flow of the liquid will cause a slight change in the propagation time, and the change in its propagation time is proportional to the flow rate of the liquid.When the flow of the two sensors is zero, the time required for the two sensors to emit and receive sound waves is exactly the same (the only technology that can actually measure zero flow).When the liquid flows, the sound wave transmission time in the countercurrent direction is greater than the sound wave transmission time in the downstream direction.
3.Fixed Ultrasonic Flow meter product features
In addition to having the general usage functions of similar products, ultrasonic flowmeters also have the following characteristics:
1.The number of sampling times per cycle has increased to 128, and the measurement results are more stable, which can meet the flow measurement needs of most clean water, sewage and a variety of chemical liquids, greatly reducing the interference of the poor detection environment on the measurement results.
2.Electrically isolated DC power supply is used to greatly improve the reliability and anti-interference of the host.For situations where there is no power supply on site, users can choose a 15W solar panel with a 24V/30AH lead-acid battery pack, and can achieve continuous power supply for cloudy days for a continuous week.
3.The measurement motherboard has a standard isolated RF-485 interface, which can support both MODBUS and M-BUS standard protocols, and is fully compatible with the communication protocol of the original ultrasonic flowmeter and the various flowmeter water meter protocols produced by the company.
4.The measurement motherboard has a serial expansion bus interface, and users can choose various function expansion modules for function expansion.The scalable functions include 4-20mA current loop output, frequency signal output, large-capacity data recording, thermal printer and other functions.
5.The motherboard has two three-wire PT100 platinum resistor input circuit, and the platinum resistor is connected to it and it becomes a complete ultrasonic calorimeter.At the same time, the temperature difference sensitivity function is added to prevent the ineffective accumulation of heat during long-term low flow rates or low temperature differences.
6.The motherboard has three analog input loops.It can input physical quantities such as pressure and liquid level, and be used as a simple RTU.
7.A fault timer (located in menu M+9) is added to the software operation window.When the instrument cannot measure normally, the time value will increase.
8.It has up to 8 different language interfaces for customers to choose from.
4.Fixed Ultrasonic Flow meter technical parameters
project | Performance, parameters | |
Host | Accuracy | 1.0% |
Repeatability | 0.2% | |
Maximum flow rate | 6m/s | |
Measurement cycle | 500ms (2 times per second, 128 sets of data are collected per cycle) | |
Measurement principle | Ultrasonic time difference principle, 4-byte IEEE754 floating point operation | |
Display interface | Can be connected to 2×10 backlight Chinese characters or 2×20 character LCD display | |
operate | External 16-key touch keyboard and PC computer settings software | |
enter | 3 channels of 4~20mA input are optional, with an accuracy of 0.1%, and can input pressure, liquid level, temperature and other signals, and can also be used as a digital interface. | |
Two-way three-wire PT100 platinum resistor input circuit can realize the heat metering function (enthalpy difference method) | ||
Output | Current signal (optional module): 4~20mA, impedance 600Ω floats, accuracy 0.1%. Frequency signal (optional module): optional between 1~9999Hz, OCT output. Pulse signal: positive, negative, net flow and heat cumulative pulses, dual OCT output (one pulse width can be programmable between 6~1000mF, default 200mF). Alarm signal: dual-channel OCT output, nearly 20 source signals can be selected. Data interface: Isolated RF485 serial interface. | |
Communication protocol | MODBUS protocol, MBUS protocol, FUJI extension protocol (compatible with Huizhong Company flow meter and water meter communication protocol), it is recommended to use MODBUF-RTU protocol or MODBUS-ASCII protocol | |
Other functions | Automatically remember the cumulative flow and working status of the first 64 days, the first 32 months, and the first 2 years; automatically remember the first 16 power-off times and the flow and can be automatically or manually added; Programmable quantitative controller (can be started using external input signals or MODBUF instructions); One bidirectional serial interface can connect multiple external devices such as 4~20mA, data recorder, etc.; The working parameters can be cured into the FLAFH memory in the machine and will be automatically called out when powered on; Users can upgrade software through code files transmitted from E-mail Fault self-diagnosis function. Failure timer. | |
Operating current | 50mA (without connecting the keyboard display and the buzzer does not ring) | |
Backup current | Using CR2032, keep data without loss of 100,000 hours under 24VDC power outage conditions | |
Ambient temperature | -10℃~70℃ (please contact the manufacturer if you are greater than this temperature range) | |
Working hours | continuous | |
sensor | Outer clip type | M2 suitable pipe diameter DN50~700mm |
Signal cable | Special, 5 meters standard for factory use, single root can be lengthened by 500 meters in specific occasions (not recommended). | |
Protection level | IP68 (can be used in water) | |
Measuring pipeline | Pipe | All densely textured pipes such as steel, stainless steel, cast iron, PVC, PE, PPR copper, aluminum, cement pipes, etc.are allowed to be lining (the plastic should be controlled as much as possible to less than 8mm, otherwise it will not be measured if it is not dense). |
Lining material | Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, polyester, polyethylene, hard rubber, bakery, polytetrafluoroethylene. | |
Linear pipe section length | Upstream ≧10D, downstream ≧5D, and ≧30D from the outlet of the pump. | |
Measuring pipeline | type | Water |
Turbidity | ≦20000ppm, the sewage measurement effect is good, and most sewage pipes can be measured stably. | |
temperature | -40℃~160℃ | |
Flow direction | The forward and reverse flows can be measured separately, and the net flow can be measured. |
The Ultrasonic weather station utilizes ultrasonic technology to measure meteorological elements. When ultrasonic waves propagate in the air, their propagation speed is affected by air flow. When the wind blows from different directions, the propagation times of ultrasonic waves in the downwind and...
Meteorology encompasses a wide range of elements, such as rain, ice, wind, frost, clouds, and temperature, among others. In the power system, "micro-meteorology" is different from what is described in meteorology. Power micro-meteorology refers to the meteorological conditions in a small s...
The construction of smart wetlands takes wetland monitoring equipment as the core, and combines Internet of Things (IoT), big data, and artificial intelligence technologies to build a three-dimensional monitoring network covering hydrology, meteorology, and ecology.The wetland weather stations...
As night fell, I was flying through the darkness as usual. Suddenly, I spotted a beam of light that lured insects ahead. Driven by instinct, my companions and I flew towards the light source without hesitation. Later I came to know that it was actually a nightmare from which there was no escape. Tha...