Model:FT-CW96A
Brand:tianqiong
Fluorescence Quantitative PCR Detection System application scenario:
Fluorescence Quantitative PCR Detection System is an onboard software for intuitive operation and intelligent analysis, using real-time fluorescence detection to analyze PCR template amplification.
Basic scientific research
Pathogen detection
Adulterated meat products
Genetically modified test
Food safety testing
Drug development and rational use of medicine
Gene expression
Water monitoring
Fluorescence Quantitative PCR Detection System Instrument Technical Indicators
Basic Performance | |
External dimensions | 410*320*196 mm |
weight | 11 Kg |
power supply | 220V |
Communication interface | USB |
Operating environment parameters | |
Operating ambient temperature | 18~35℃ |
Relative humidity in the operating environment | 0%~85% |
Transportation and storage temperature | -20~55℃ |
Transport and storage relative humidity | 0%~85% |
System Performance | |
Sample capacity | 96 wells*0.2ml |
Sample volume | 20~120ul |
Suitable consumables | 0.2ml single tube, 8×0.2ml drain pipe |
Temperature control range | 4~99℃ |
Temperature control accuracy | ±0.1℃ |
Average heating rate | 3.5 ℃/s |
Average cooling rate | 3 ℃/s |
Fluorescence detection system performance | |
light source | High brightness LED |
Detector | Photomultiplier tube |
Excitation light wavelength | 460nm~480nm, 525nm~545nm, 575nm~595nm, 600nm~620nm |
Detect light wavelength | 505nm~525nm, 555nm~575nm, 600nm~620nm, 660nm~680nm |
Fluorescence Quantitative PCR Detection System main technical parameters (★ represents the parameters that must be met)
★1.1 Sample tank: adopts high-spec aluminum alloy sample tank, with good thermal conductivity, corrosion resistance and oxidation resistance, Peltier heating and temperature control, and a comprehensive sealing design. Whether it is sample solution or condensate, it will not leak into the Peltier temperature control components and other electronic components under the sample tank, which can effectively extend the service life of the instrument.
★1.2 Accurate temperature control system: adopts a high-precision PT1000 temperature sensor, with a temperature control accuracy of 0.01℃, fully ensuring the accuracy of temperature control.
1.3 Sample flux: 96×0.2ml PCR tube, 96-well plate, 12×8 tube.
1.4 Open reagent consumables system: You can choose any brand of reagents, suitable for standard 96-well plates, 8-link tubes or 0.2ml PCR single tubes
★1.5 High-intensity wide spectrum excitation light source: four high-intensity long-life LED solid-state light sources are adopted, blue, green, red and yellow, to ensure strong light intensity in the entire spectrum detection range, improve detection sensitivity, and do not generate heat, have a long service life, and are maintenance-free for life
1.6 High sensitivity detector: Use high sensitivity photomultiplier tube imported from Japan, with higher detection sensitivity
1.7 No optical path correction required: The scanning system can ensure that the signal excitation and detection optical path of each hole are completely consistent, and no optical path correction is required, so there is no need to occupy an additional correction channel, which can achieve true four-channel gene detection.
★1.8 Number of channels: 4 channels are configured.
1.8.1 Channel crosstalk: Use high-precision narrow waveband filter to minimize channel crosstalk. The software can also correct crosstalk parameters
★1.9 Detection sensitivity: Can detect single-copy DNA templates, and can clearly distinguish 1000 copies and 2000 copies of plasmid DNA
★1.10 Linear detection range: 10 orders of magnitude
1.11 Available technical methods: Support commonly used fluorescent dyes and probe detection methods, such as SYBR Green I, Eva Green, Taqman, FRET, Molecular Beacons, Scorpions, Amplifluor, etc.
1.12 module temperature range: 4 - 99 ℃
1.13 Control Mode: Windows Computer
1.14 interface: Computer USB connection
1.15 Working noise: Silent technology, the maximum working noise during operation shall not exceed 45 dB
1.16 Operation analysis software
1.16.1 You can define sample holes after running the program, saving experimental time
1.16.2 When running the program, you can open other experimental data results for review and analysis.
1.16.3 The software automatically calculates the baseline range and automatically sets the threshold line to provide users with reliable and accurate data results.
★1.16.4 The experimental program setting information and detection results can be printed directly into experimental reports, supporting export of various file formats and data styles such as XLS, CSV, WORD and other files and data styles.
1.16.5 The results of the same batch of experiments can be grouped for independent data analysis, and can be divided into up to 12 groups.
★1.16.6 provides Chinese and English software interface.
★The 1.16.7 software can be installed on multiple computers without restrictions, and there is no need to pay to purchase and use rights, and can be upgraded for free for life.
2 Basic configuration:
2.1 Quantitative PCR instrument host
2.3 Operating Instructions
2.4 Power cord and data cord
2.5 One set of operation analysis software
The Ultrasonic weather station integrates various sensors with different functions, such as sensors for measuring wind speed and direction, sensors for detecting temperature and humidity, and sensors for recording rainfall, etc., all in the same device. This design makes the structure of the weather...
In today's society, environmental problems are becoming more and more serious. From air pollution to water quality deterioration, from soil pollution to noise interference, these issues seriously affect the survival and development of human beings. As an important cornerstone of environmental pr...
In the modern industrial field, the chemical industry has an extremely high demand for meteorological monitoring. The chemical production process is complex and involves many flammable, explosive, and corrosive chemical substances. For example, in a chemical industrial park, under different meteorol...
The construction of smart wetlands takes wetland monitoring equipment as the core, and combines Internet of Things (IoT), big data, and artificial intelligence technologies to build a three-dimensional monitoring network covering hydrology, meteorology, and ecology.The wetland weather stations...